Field ServicesOur service department representatives have over 40 years of heat exchanger experience.
Regardless of brand or model, our service department team understands the requirements for proper
installation, operation and maintenance. Building on global technology, we give customers a
guarantee of receiving the best possible cooler performance unmatched by any other service
organization. GEA Rainey Corporation offers several different field service solutions. However, we
recognize each individual customer has different needs. GEA Rainey Corporation can customize a
field service solution for each individual customer.
Commissioning and Start-Up Assistance
For new and/or replacement equipment manufactured by GEA Rainey Corporation, a recommended
field service solution is commissioning and start-up assistance. Our experienced field service team
provides on-site supervision for installation. All equipment manufactured by GEA Rainey Corporation
must pass a rigorous inspection by our Quality Control Department before release for shipment.
However, a comprehensive inspection of the air cooler components after shipment and installation by
our expert field service team is a logical measure to assure safe start-up and efficient
operation.
Our commissioning and start-up assistance services can include, but are not limited to:
Operator & Maintenance Personnel Training
Our training courses are designed to cover the design, operation and maintenance of air cooled
heat exchangers. Curriculum is customized to address the specific equipment at a facility. The goal
of this training course is to provide a better overall understanding of the operating and
maintenance requirements of air cooled heat exchanger equipment. This enables plant personnel to
obtain the best possible performance and avoid costly maintenance downtime. In addition to
classroom instruction, we believe hands-on training delivered in the plant is an effective addition
to the principles and theory learned in the classroom.
Capacity Measurement
In many cases air cooled heat exchangers represent bottlenecks to a plant process. Even when
cooler performance remains acceptable, a cooler’s capacity can drop below a critical level.
Additional equipment, changes in production or other factors play significant roles in performance.
Our service team has experience identifying limiting factors of a process. After an extensive
evaluation of the equipment and process conditions, our technicians offer advice and provide
practical, cost-effective solutions for performance enhancement of existing coolers.
Our capacity measurement service methodology:
The second tier of our capacity measurement service methodology is evaluating results and
making recommendations. Two examples are process upgrades and process control enhancements.
Re-Rating Pressure Vessels
Air coolers typically have an average life of 20-25 years depending on the service type and
installation location. It is not uncommon for plant process conditions to change several times
during the service life of an air cooler. For ASME code stamped pressure vessels manufactured by
GEA Rainey, our service department provides a re-rate service. If your process conditions have
changed and any of these conditions exceed the original ASME nameplate values on your air cooler,
please contact our service department.
Periodic Inspections
Routine maintenance is the key for assuring optimal performance. We offer two service models;
inspection or maintenance. For an inspection contract, our experts evaluate the air cooler, record
findings and make maintenance recommendations as applicable. The maintenance contract simply
extends our inspection requirements to include normal cooler maintenance. This comprehensive field
service solution is customized to work with customer’s internal programs as required.
Vibration Testing
Vibration can cause excessive wear on mechanical components of air cooled heat exchangers.
Over time, vibration can also weaken and crack structural members of the equipment. Not all
vibration is harmful. GEA Rainey Corporation’s vibration testing service solution is designed to
measure harmful sources of vibration and identify the cause of the vibration. Recommendations
and/or corrections are made to eliminate the vibration. Elimination of harmful vibration can extend
the life of the mechanical and structural components of the air cooler as well as assuring
continuous, safe operation of the equipment.
Noise Reduction
Noise is becoming an increasingly important environmental factor. GEA Rainey Corporation's
trained technicians can evaluate each situation and provide recommendations for potential noise
reductions without any loss in cooling capacity.
|
|
||||||||